¢J
IGT002 Type
DELTA ELECTRONICS, INC.
(TAOYUAN PLANT CPBG)
70
Via the system-provided input voltage 230-240V, the high voltage coil is stimulated
and gives the voltage output between 14KVo-p & 25KVo-p to start up the ignition system
of the gas furnance or the molecule ozonization of air cleaning M/C.
Features
Gas Igniter
Oil Igniter
Air Cleaner
Electronic Ozonizer
Applications
Mechanical Dimension:
Unit: mm
17.0 0.5
33.0 Max.
29.0 Max.
4.0 0.5
25.0 0.5
18.5 0.5
1 2
b
a
1.2
1
2
3
4
PRI
SEC
H.V.
Schematic :
4
3
2 1
Electrical Characteristics:
252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com
PART NO.
PRIMARY
PRIMARY
INDUCTANCE (uH)
¢J
PRIMARY SECONDARY PRIMARY SECONDARY WEIGHT
PART NO.
INDUCTANCE (uH) INDUCTANCE (mH) DCR (m ) MAX. DCR ( ) MAX.
IGT-002 26.7 25% 94.0 25% 65 165 38g
25.0 Max.
23.8 0.5
o
AT 25 C, 65%RH, INDUCTANCE TESTED@1KHz/1V
oo
Operation temperature: -40C to +105C
oo
Storage temperature: -20C to +85C
Input voltage: 240 Vdc
No-load voltage: 14KV min.
Insulated with epoxy resin
Recommended Circuit:
+
-
240 Vdc
SUPPLY
DC
SW1
C1
2.2nf
SW2
1
2
T1
OUTPUT
50pf
4
3
C2
Ignition Coil