Delta Electronics Ethernet Extension Module DOP Specifications Page 135

  • Download
  • Add to my manuals
  • Print
  • Page
    / 175
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 134
Train ing Kit O peratio n Manua l
5-8
4. Program description
The ground floor and the basement share the same red light signal Y1 and green light
signal Y2.
The key of the program is to judge whether the car is entering or leaving the passage at the
ground floor entry/exit when M1 is ON to activate Y1 because [PLS M1] will be executed in
both entering and leaving conditions. Therefore, the confirming signal M20 is required for
confirming that the car is entering the passage from the ground floor.
Also, it needs to be judged whether the car is entering or leaving the passage at the
basement entry/exit when M3 is ON because [PLS M3] will be executed in both entering
and leaving conditions. Therefore, the confirming signal M30 is required for confirming that
the car is entering the passage from the basement.
Page view 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 174 175

Comments to this Manuals

No comments