DATASHEET
DS_E48SR05012_05222008
FEATURES
High Efficiency: 91.5% @ 5.0V/12A
Size: 58.4mmx22.80mmx8.4mm
(2.30”x0.90”x0.33”)
Standard footprint
Industry standard pin out
Fixed frequency operation: 350KHz
Input UVLO, Output OCP, OVP, OTP
1500V isolation
Basic insulation
No minimum load required
2:1 Input voltage range
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing
facility
UL/cUL 60950-1 (US & Canada)
recognized, and TUV (EN60950-1) certified
CE mark meets 73/23/EEC and 93/68/EEC
directive
APPLICATIONS
Telecom/Datacom
Wireless Networks
Optical Network Equipment
Server and Data Storage
Industrial/Testing Equipment
OPTIONS
SMT or through-hole versions
Positive on/off logic
Short pin lengths
Delphi Series E48SR, 66W Eighth Brick Family
DC/DC Power Modules: 48V in, 5.0V/12A out
The Delphi Series E48SR Eighth Brick, 48V input, single output, isolated
DC/DC converter is the latest offering from a world leader in power
systems technology and manufacturing – Delta Electronics, Inc. This
product family provides up to 66 watts of power or 25A of output current
(1.8V and below) in an industry standard footprint. With creative design
technology and optimization of component placement, these converters
possess outstanding electrical and thermal performances, as well as
extremely high reliability under highly stressful operating conditions.
All
models are fully protected from abnormal input/output voltage, current,
and temperature conditions. The Delphi Series converters meet all safety
requirements with basic insulation.
Page view 0
1 2 3 4 5 6 ... 14 15

Summary of Contents

Page 1 - OPTIONS

DATASHEET DS_E48SR05012_05222008 FEATURES  High Efficiency: 91.5% @ 5.0V/12A  Size: 58.4mmx22.80mmx8.4mm (2.30”

Page 2 - TECHNICAL SPECIFICATIONS

DS_E48SR05012_05222008 10 FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, the

Page 3

DS_E48SR05012_05222008 11 THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operati

Page 4

DS_E48SR05012_05222008 12 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD)

Page 5

DS_E48SR05012_05222008 13 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE Time ( sec. ) Pre-heat temp. 140~180°C 60~120 sec. Peak temp. 210~230°C 5s

Page 6

DS_E48SR05012_05222008 14 MECHANICAL DRAWING Surface-mount module Through-hole module Pin No. Name Function 1

Page 7

DS_E48SR05012_05222008 15 PART NUMBERING SYSTEM E 48 S R 050 12 N R F A Type of Product Input Voltage Number of Outputs Product Series Outp

Page 8 - DESIGN CONSIDERATIONS

DS_E48SR05012_05222008 2 TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.) PARAMETER NOTES

Page 9 - FEATURES DESCRIPTIONS

DS_E48SR05012_05222008 3 ELECTRICAL CHARACTERISTICS CURVES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at

Page 10

DS_E48SR05012_05222008 4 ELECTRICAL CHARACTERISTICS CURVES For Negative Remote On/Off Logic Figure 4: Turn-on transient at full rated load curre

Page 11

DS_E48SR05012_05222008 5 ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, m

Page 12 - RECOMMENDED PAD LAYOUT (SMD)

DS_E48SR05012_05222008 6 ELECTRICAL CHARACTERISTICS CURVES Figure 11: Input Terminal Ripple Current, ic, at full rated output current and nomina

Page 13 - DS_E48SR05012_05222008

DS_E48SR05012_05222008 7 ELECTRICAL CHARACTERISTICS CURVES Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=12

Page 14 - MECHANICAL DRAWING

DS_E48SR05012_05222008 8  The input source must be insulated from the ac mains by reinforced or double insulation.  The input terminals of

Page 15 - MODEL LIST

DS_E48SR05012_05222008 9 FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, w